Under the revised MARPOL Annex I which entered into force on 1 January 2007, what oil pollution prevention equipment must be fitted in a ship of 10, 000 GT or more?
30
Wed, Dec
0 New Articles
 

Under the revised MARPOL Annex I which entered into force on 1 January 2007, what oil pollution prevention equipment must be fitted in a ship of 10, 000 GT or more?

MCA Oral Exam Questions
Typography

(1) Oil filtering (15 ppm) equipment of a design approved by the flag State Administration; (2) an alarm arrangement to indicate when 15 ppm cannot be maintained; and (3) arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 (MARPOL Annex I, reg. 14.2)